Ships across Canada · Prices in CAD · Tax by province

Buying guide · Sauna heaters & wood stoves

What size sauna heater do I need?

Products in this guide

Plan on about 1 kW of heater for every cubic metre of sauna room (about 35 ft³), then let the heater's published room range make the final call. Measure inside the room, add 1.2 m³ for each square metre of glass or bare masonry, multiply by 1.5 if the walls are solid logs, and choose a heater whose range covers the result, ideally near the middle. A 2 × 2 m room with a 2.1 m ceiling is 8.4 m³ (297 ft³), which sits near the middle of the range of an 8 kW Harvia Cilindro or a 7.5 kW HUUM DROP 7.

The calculator below does the arithmetic. The tables further down list the room range of every size in the heater families we carry, and the heater size each sauna maker names for its own saunas. Breakers, wire and permits have their own guide: sauna electrical requirements in Canada.

Work out your heater size

Measure inside the finished sauna, wall to wall and floor to ceiling, not the outside of the building.

  • Room volume: length × width × height. If you measure in feet, multiply the three and divide by 35.3 to get cubic metres.
  • Glass and masonry: add up the width × height of every glass door, window and bare stone, brick, tile or concrete wall. A glass sauna door counts in this sum; a solid wooden sauna door does not. Cedar panelling over insulation doesn't count.
  • Solid log or solid timber walls: tick the box. Barrel saunas count here only when the sauna maker doesn't name a heater size, and most do (see the second table below).

The calculator gives you a sizing volume and a typical kW band. Then check that volume against the room range of the heater you're looking at.

Sauna heater size calculator

Measure inside the sauna, wall to wall and floor to ceiling.

Measure in

Width × height of each glass door, window or bare masonry wall, added up. A 2 × 6.5 ft glass door is 13 sq ft.

Barrel saunas count here only when the sauna maker doesn't name a heater size. If it does, start from that.

Room volume
not calculated yet
Sizing volume
not calculated yet

Typical heater size

not calculated yet

Enter the length, width and height to see your sizing volume and a typical heater size.

Choose a heater whose published room range includes your sizing volume, ideally near the middle of that range. Wood stoves are rated differently: use the stove's own room range.

How it works: room volume, × 1.5 for solid log walls, plus 1.2 m³ for every m² of glass or bare masonry (Harvia's published method; HUUM adds 1 m³ instead). The top of the band is the common rule of about 1 kW per m³; the bottom is 25% lower. The heater's manual and its published room range always decide, and a licensed electrician sizes the circuit.

Why about 1 kW per cubic metre

Harvia, the Finnish heater maker, puts it simply: on average a sauna needs about 1 kW of heater output per cubic metre of room (Harvia support). Some US guides use a looser rule of about 1 kW per 45 ft³, which is about 1.3 m³ (Sauna Times). Neither rule replaces the heater's own table, because each heater is tested and rated for a range of rooms.

The makers agree on what happens when the size is wrong:

  • Too small: the heater works at full power for longer to reach temperature, and Harvia says an undersized heater has a shorter life.
  • Too big for the room: HUUM's manual says the warranty is void if the heater's output doesn't match the room volume (HUUM DROP manual).
  • About right: Harvia suggests a heater whose range puts your room near the middle, not at the very bottom or top.

Add volume for glass, stone and log walls

Glass and bare masonry don't hold heat the way an insulated wall does, so the makers ask you to size for a bigger room:

  • Harvia: add 1.2 m³ for every m² of glass, stone or other uninsulated surface, and multiply the volume of a solid log sauna by 1.5 (Harvia support; Harvia's Cilindro manual).
  • HUUM: add 3.3 ft³ for every ft² of uninsulated wall such as glass, stone or tile, which works out to about 1 m³ per m² (HUUM DROP manual).

Our calculator uses Harvia's 1.2 figure. The difference is small, but if you're buying a HUUM, use HUUM's own rule.

Example: a room with a glass door

Harvia's own example is a room 2.0 × 2.5 m with a 2.3 m ceiling: 11.5 m³. A 0.9 × 2.1 m glass door is 1.89 m², and 1.89 × 1.2 adds 2.27 m³, for a sizing volume of about 13.8 m³ (486 ft³). That is above every HUUM DROP range (the DROP 9 stops at 13 m³) and near the top of the 9 kW Harvia's 4–14 m³. The 10.5 kW Harvia, rated for 4–18 m³, puts the room closer to the middle.

Example: solid log walls

A solid-log room 2 × 2 m with a 2 m ceiling is 8 m³. Multiplied by 1.5, it sizes like a 12 m³ room: inside the range of the 9 kW and 10.5 kW Harvia, and of the HUUM DROP 9 (8–13 m³).

Room ranges for the heaters we carry

The first table below lists every size in each heater family, with the room range from the current North American manual. A few things stand out:

  • Harvia's ranges are wide. Every Cilindro size starts at 4 m³ and every Virta size at 5 m³, so most rooms fit two or three sizes. Use the middle of the range to choose.
  • HUUM's ranges are narrow and step up with the size, from the DROP 4 at 3–7 m³ to the DROP 9 at 8–13 m³ (HUUM DROP manual).
  • The smallest rooms: Harvia Vega Compact. The Harvia Vega Compact 1.9 kW is rated for 2–3 m³ and the 3.5 kW for 2–5 m³ (Harvia's manual), with the timer and thermostat built in.
  • Homecraft suits small rooms. The Revive Slim 4 kW is rated for 2.4–5 m³. Homecraft also gives slightly different ranges from its manual; we use the current manual (Revive Slim manual).
  • Ceiling height counts. The Cilindro needs a room at least 1900 mm (75 in) high, or 1980 mm (78 in) for the 10.5 kW, and Harvia's room guide says no higher than 2300 mm (7 ft 6 in) (Harvia's North American Cilindro manual).

Each product page shows which sizes we list, or browse all sauna heaters.

If your sauna maker names a heater size, start there

Barrel and outdoor cabin saunas usually come with a recommended heater. The maker knows its own wall thickness, glass and shape, so start from that number. The second table below lists it for the saunas we sell, from Leisurecraft's spec sheets.

Two things we noticed while checking:

  • Some makers recommend more than 1 kW per m³. Leisurecraft names 7.5 kW for the 5.89 m³ (208 ft³) MiniPOD and 9 kW for the 7.5 m³ (266 ft³) Panoramic. Follow the maker, not the rule of thumb.
  • Bigger isn't an upgrade. An 8–9 kW heater is oversized for a sauna that Leisurecraft rates for 6 or 7.5 kW. The HUUM DROP 9, for example, is rated for rooms from 8 m³ (283 ft³), larger than either of those saunas.

For the Leisurecraft Red Cedar Barrel Sauna (5.5 m³, 193 ft³), Leisurecraft doesn't state a heater size, so ask before you buy one.

Between two sizes? Aim for the middle

  • Harvia's own example: a 9.5 m³ room fits both the PC70 and the PC90 Cilindro, and Harvia recommends the PC90 (9 kW) because the room sits nearer the middle of its range (Harvia support).
  • Replacing a wall-mounted heater with a free-standing one such as the Cilindro? Harvia suggests going up about 1 kW.
  • An outdoor sauna in January starts from a colder room, but none of the manuals we used gives a separate cold-weather adjustment. Stay inside the heater's published range rather than oversizing.
  • The size you choose also sets the circuit, so check what your electrical panel can supply before you settle on one. See sauna electrical requirements.

Wood-burning stoves are rated differently

A wood stove's kW figure isn't comparable with an electric heater's. The Harvia Legend 150 is rated at 16 kW for rooms of 6–13 m³ (212–459 ft³) (Harvia), so use the stove's own room range, not the kW.

It needs a chimney rather than a circuit. Its manual shows European certification (EN 15821). Like every wood sauna stove we could find on sale in Canada, it has no Canadian listing, so it is installed to CSA B365 with larger clearances and most insurers want a WETT inspection; ask your municipality and your home insurer before you buy. More in wood vs electric sauna heaters.

Infrared saunas skip this step

An infrared sauna comes with its heaters built in and sized by the maker, so there is nothing to calculate. What matters is the circuit it needs, which is in the electrical guide. Browse infrared saunas, or compare the two kinds in infrared vs traditional sauna.

Safety notes

  • Never disable or bypass a heater's high-limit switch, thermostat or timer. Ontario's Electrical Safety Authority links tampering like this to sauna fires (ESA Flash 25-20-FL).
  • Keep towels and other combustibles out of the sauna when it isn't in use, and keep the clearances in the heater's manual.
  • Sauna heat isn't for everyone. Skip alcohol, and talk to your doctor first if you have a heart condition or another medical condition, or are pregnant.

Comparison tables

Room ranges by heater size

Scroll the table sideways to see every column.

Room volumes from each maker's current manual; middle of range is our arithmetic. Add volume for glass and log walls first. Checked 15 Nov 2026.
HeaterOutputRoom volume (m³)Room volume (ft³)Middle of range
Harvia Cilindro6.0 kW4–8141–2946 m³
Harvia Cilindro6.8 kW4–10141–3547 m³
Harvia Cilindro8.0 kW4–12141–4318 m³
Harvia Cilindro9.0 kW4–14141–4949 m³
Harvia Cilindro10.5 kW4–18141–63611 m³
Harvia Virta6.0 kW5–8177–2946.5 m³
Harvia Virta6.8 kW5–10177–3547.5 m³
Harvia Virta8.0 kW5–12177–4318.5 m³
Harvia Virta9.0 kW5–14177–4949.5 m³
Harvia Virta10.5 kW5–18177–63511.5 m³
HUUM DROP 44.5 kW3–7106–2485 m³
HUUM DROP 66 kW5–9177–3187 m³
HUUM DROP 77.5 kW7–11248–3899 m³
HUUM DROP 99 kW8–13283–46010.5 m³
Homecraft Revive Slim4 kW2.4–5100–1753.7 m³
Homecraft Revive Slim5 kW4.3–7.8150–2756.05 m³
Homecraft Revive Slim6 kW7.1–9.4250–3318.25 m³
Harvia Legend 150 (wood)16 kW6–13212–4599.5 m³

Heater size named by the sauna maker

Scroll the table sideways to see every column.

Interior volumes and recommended electric heater sizes from Leisurecraft's spec sheets, checked 15 Nov 2026.
SaunaInterior volumeRecommended heater
Leisurecraft Indoor Cabin Sauna, 4 × 6 ft3.96 m³ (140 ft³)4.5 kW (other sizes: 4.5–9 kW)
Leisurecraft Red Cedar Barrel Sauna5.5 m³ (193 ft³)Not stated: ask the maker
Canadian Timber MiniPOD5.89 m³ (208 ft³)7.5 kW
Canadian Timber Harmony barrel6.3 m³ (222 ft³)6 kW
Leisurecraft Pure Cube6.4 m³ (227 ft³)6 kW
Leisurecraft Panoramic barrel, 7 × 6 ft6.5 m³ (230 ft³)7.5 kW
Leisurecraft Panoramic barrel, 7 × 7 / 7 × 8 ft7.5 / 8.5 m³ (266 / 303 ft³)9 kW
Canadian Timber Tranquility barrel7.6 m³ (297 ft³)7.5 kW
Canadian Timber Georgian cabin9.7 m³ (343 ft³)9 kW

Questions

What size sauna heater do I need for a 2 × 2 m room?

It depends on the ceiling. With a 2.1 m ceiling the room is 8.4 m³ (297 ft³), and the calculator suggests about 6–8.5 kW. That volume sits near the middle of the 8 kW Harvia Cilindro (4–12 m³), the HUUM DROP 7 (7–11 m³) and the Homecraft 6 kW (7.1–9.4 m³). Add volume for any glass door first.

What size heater do I need for a 6 × 6 ft sauna?

With a 7 ft ceiling, 6 × 6 × 7 ft is 7.1 m³ (252 ft³), and the calculator suggests about 5–7.5 kW. Heaters whose range puts that near the middle include the 6.8 kW Harvia Cilindro (4–10 m³) or Virta (5–10 m³) and the HUUM DROP 6 (5–9 m³). Add volume for glass first.

Is a bigger sauna heater better?

No. Choose the size whose published range puts your room near the middle. An oversized heater can void the warranty: HUUM's manual says so when the output doesn't match the room volume (HUUM DROP manual). A bigger heater also needs a bigger circuit.

How much does a glass door change the heater size?

Harvia adds 1.2 m³ for every square metre of glass. A typical 0.7 × 1.9 m glass door is about 1.3 m², so it adds about 1.6 m³ to the sizing volume. HUUM's rule adds a little less, about 1 m³ per m².

What size heater does a barrel sauna need?

Use the size the sauna maker names. Leisurecraft recommends 6 kW for the Harmony barrel (6.3 m³) and 7.5 kW for the Tranquility (7.6 m³). If the maker gives no size, run the calculator with the solid-wall box ticked and confirm with the maker before you buy.

How do I convert cubic feet to cubic metres?

Divide cubic feet by 35.3. A 200 ft³ room is about 5.7 m³, and 1 m³ is about 35.3 ft³. The calculator accepts feet or metres and shows both.

Does an outdoor sauna in Canada need a bigger heater?

Not by any rule the makers publish. None of the heater manuals we used adds a cold-weather allowance. Stay inside the heater's published room range, add volume for glass, and follow the sauna maker's recommended size where there is one.

Does a bigger heater need a bigger breaker?

Yes. More kilowatts means more current, so the breaker and wire grow with the heater. Choose the heater size first, then have a licensed electrician size the circuit from its manual. Our electrical requirements guide lists the numbers for each heater.

Shop sauna heaters & wood stoves

Sources

Models in this guide

More guides