Harvia
The Harvia Legend 150 is a 16 kW wood-burning sauna stove for rooms of 6–13 m³, with a black steel frame that holds 120 kg of stones around the fire. It needs no electricity but needs a chimney. Like every wood sauna stove sold in Canada, it has no Canadian listing, so ask your insurer and inspector before you buy.
$2,304
Stove alone
$2,730.60 with the stones it needs to run
CAD, before tax · free delivery in the provinces
Pay by card or Interac e-Transfer at checkout.
Return terms are published before we open. Shipping and returns
Available to order
Item no. KL-WK150LD
Total for the stove and stones: $2,730.60
Delivery and tax
From the maker's documents. Check permits with your town and wiring with a licensed electrician.
No electrical connection: it burns wood. It needs a T600-class chimney on its 115 mm collar (with an adapter for 6-inch North American pipe) and air for combustion.
Ø 530 mm, 740 mm tall plus legs, for a 6–13 m³ room. Harvia's manual asks for 200 mm to the sides, 250 mm behind, 500 mm in front and 1000 mm above to combustibles, 50 mm to masonry (100 mm in a recess), and 500 mm around the smoke pipe (250 mm with Harvia's WZ020130 radiation cover). Installed to CSA B365 as an unlisted stove, the clearances will be larger: your inspector sets them.
Installing a wood stove usually needs a building permit, and a new sauna building may need one too. Your inspector applies CSA B365 because the stove has no Canadian listing, and your insurer may want a WETT inspection. See sauna permits in Canada.
Ships by freight; the stove weighs 58–61.5 kg before stones. The stones, chimney adapter and chimney are separate items.
Set it on its legs, connect the chimney at the rear or top, add floor protection if needed and load the stones. Harvia does not say who must install it; follow the manual, CSA B365 and your local building and fire codes, and plan for the inspection.
The Legend 150 (Harvia code WK150LD) is a wood-burning sauna stove from Finland. A round black steel frame, 530 mm across and 740 mm tall, holds up to 120 kg of stones around the fire chamber, and a cast-iron door with glass lets you see the fire. It is rated at 16 kW for a sauna room of 6–13 m³ (212–459 ft³).
It needs no electrical circuit, which suits a cottage, a cabin or a sauna building without heavy electrical service. In exchange it needs a chimney, space around it and approval from the people who sign off on wood heat where you live.
It is one of several sauna heaters we carry, and the only wood-burning one. Planning a sauna at the lake? Our cottage sauna guide covers the wider choices.
No. The Legend 150 has no Canadian listing. Harvia states CE marking to the European standard EN 15821 (tested by VTT, Declaration of Performance DoP09LG150) and the Eurasian EAC mark. No ULC-S627, UL 1482 or CSA B366 listing is stated for it.
This is not special to the Legend. As far as our research and Canadian sauna-stove makers can tell, no wood sauna stove sold in Canada carries a Canadian safety listing. What that means in practice:
Ask your insurer and your building inspector before you buy, not after. We will not tell you the stove is approved, because no Canadian listing is published. If either says no, an electric heater with a published North American mark is the simpler route.
Harvia rates the Legend 150 for a room of 6–13 m³ (212–459 ft³), with a minimum room height of 2.0 m (6.56 ft). Our sauna heater size guide shows how to work out your volume.
Harvia says the large stone mass keeps giving heat even when the fire dies down between loads.
The chimney is the part of a wood stove install that surprises buyers most:
Harvia's declared figures help your installer size the chimney: flue gas 420 °C, chimney draught 12 Pa, efficiency 67 %. Have your inspector confirm which chimney they accept before you buy the stove.
The Legend 150 has no water tank. Harvia lists these options, none of them included. Two have their own pages here; we quote the others with the stove:
The Legend 150 suits a traditional sauna in a room of 6–13 m³ where you want the fire, a large stone mass and no 240 V circuit, and where the inspector and insurer have said yes. All the barrel saunas we sell take wood heat, the Canadian Timber Harmony among them.
Pick something else if:
No 240 V circuit is needed, which helps where the sauna building has no electrical service to spare. It still needs a chimney, an inspection and your insurer's yes.
With 120 kg of stones in a room of 6–13 m³, the stove holds heat between loads of wood, per Harvia.
Add the optional WP250LD 25 L tank on the smoke pipe, or a pipe-model water heater, to warm water while the sauna heats.
| Specification | Value |
|---|---|
| Stove | |
| Type | Wood-burning sauna stove, black steel frame holding the stones, cast-iron glass door; no electrical connection |
| Nominal output | 16 kW |
| Harvia codes | WK150LD (item), LE150 (type) |
| Room | |
| Room volume | 6–13 m³ (212–459 ft³) |
| Minimum room height | 2.0 m (6.56 ft), as Harvia states |
| Specification | Value |
|---|---|
| Dimensions | |
| Size | Ø 530 mm, height 740 mm plus 0–30 mm adjustable legs (20.87 × 20.87 × 29.13 in) |
| Weight without stones | Harvia gives two figures: 58 kg / 128 lb (manual) and 61.5 kg / 135.6 lb |
| Stones | |
| Stone load | Up to 120 kg (264.6 lb), Ø 10–15 cm (4–6 in); six 20 kg boxes; not included |
| Fire chamber | |
| Firewood | Max 35 cm (13 3/4 in) long, Ø 8–15 cm (3–6 in) |
| Cover thickness | 5 mm |
| Chimney | |
| Chimney class | T600 |
| Flue connection | Ø 115 mm (4 1/2 in) collar; min flue 110 mm inside; rear or top; no shared flue |
| North American chimney | 6 in (152 mm) pipe needs a 4-in to 6-in adapter; not included |
| Performance (EN 15821) | |
| Declared values | Flue gas 420 °C; efficiency 67 %; draught 12 Pa; ignition load 2.7 kg; refuel load 3.2 kg; flue gas flow 14.5 g/s |
| Clearances | |
| To combustibles | Ceiling 1000 mm (39 3/8 in); sides 200 mm (7 7/8 in); back 250 mm (9 13/16 in); front 500 mm (19 11/16 in) |
| To masonry | 50 mm (2 in); 100 mm (4 in) in a recess |
| Smoke pipe | 500 mm (19 11/16 in) to combustibles; 250 mm (9 13/16 in) with WZ020130 radiation cover |
| Floor | |
| Requirements | Concrete ≥ 60 mm with no wires or pipes: nothing extra. Tile: WL100 bedding or similar. Combustible: bedding plus non-flammable protection in front of the door |
| Water | |
| Water heater | None built in; WP250LD 25 L tank or pipe-model water heater optional |
| Certification | |
| Marks stated | CE to EN 15821:2010 (VTT 0809, DoP09LG150) and EAC; no Canadian or US wood-stove listing stated |
| Canadian install | Unlisted: installed to CSA B365 with its larger clearances; insurer may ask for a WETT (APC in Quebec) inspection |
| Warranty | |
| Terms | 2 years family use; 6 months commercial (Harvia, Nov 2025) |
| Codes | |
| GTIN | 6417659012416 |
From the maker's published specs. Anything not listed isn't published.
Canada-wide freight delivery; we confirm the method by email before it ships. Available to order. Delivery is free in the provinces. Yukon, the Northwest Territories and Nunavut add $600 per order. Shipping and returns
Sizes are length (front to back) × width × height. Scroll the table sideways to see every model.
| Detail | This oneHarvia Legend 150 Wood-Burning Sauna Stove, 16 kW (WK150LD) | Harvia Virta Sauna Heater, 6–10.5 kW (HL) | Homecraft Sauna Heater: Revive Slim, 4–6 kW |
|---|---|---|---|
| Price (CAD) | $2,304$2,730.60 with stones | From $2,224.80From $3,549.60 with control and stones | From $1,440From $2,182.50 with control and stones |
| Type | Wood-fired | Electric 240 V | Electric 240 V |
| Design | Wood-burning sauna stove, black steel frame holding the stones, cast-iron glass door; no electrical connection | Electric floor-standing heater, black steel body, elements separate from the stones; separate control required | Electric floor-standing tower heater for traditional saunas |
| Room size | 6–13 m³ (212–459 ft³) | 6 kW: 5–8 m³ (177–294 ft³)8 kW: 5–12 m³ (177–431 ft³)9 kW: 5–14 m³ (177–494 ft³)10.5 kW: 5–18 m³ (177–635 ft³) | 4 kW: 2.4–5 m³ (100–175 ft³)5 kW: 4.3–7.8 m³ (150–275 ft³)6 kW: 7.1–9.4 m³ (250–331 ft³) |
| Weight | Harvia gives two figures: 58 kg / 128 lb (manual) and 61.5 kg / 135.6 lbwithout stones | 23 kg (50.7 lb) for 6–9 kW; 25 kg (55.1 lb) for 10.5 kWwithout stones | 16 kg (35 lb) without rocks, all sizes |
| Stone load | Up to 120 kg (264.6 lb), Ø 10–15 cm (4–6 in); six 20 kg boxes; not included | 50 kg (110 lb) for 6–9 kW; 70 kg (154 lb) for 10.5 kW | Up to 45 kg (100 lb), 4 boxes; sold separately |
| Codes | WK150LD (item), LE150 (type) | HL6U1UL, HL8U1UL, HL9U1UL, HL11U1UL (manual prints them without UL); HL11U3 is 208 V three-phase | Not published |
| Room height | 2.0 m (6.56 ft), as Harvia states | Min 1900 mm (75 in) | Not published |
| Size (L × W × H) | Ø 530 mm, height 740 mm plus 0–30 mm adjustable legs (20.87 × 20.87 × 29.13 in) | Not published | 19 × 34 × 91 cm (7.5 × 13.5 × 36 in); some Homecraft documents give 20 cm (8 in) deep |
| Delivery | Canada-wide freight delivery; we confirm the method by email before it ships | Canada-wide carrier delivery; we confirm the method by email before it ships | Courier delivery |
The Legend 150 SL (WK150LDSL) has a through-wall firebox, so you feed the fire from another room or from outside. Harvia lists it at 730 mm deep and 65.1 kg, for the same 6–13 m³ and 120 kg of stones. We do not list it; ask us for a quote.
Harvia makes bigger Legend stoves, such as the Legend 240, for larger rooms. We do not list them; ask us and we will quote the size for your room, with the same Canadian listing caveat.
An electric heater like the Cilindro, the Harvia Virta or the HUUM DROP needs a 240 V circuit and an electrician, but no chimney, and publishes a North American mark. See wood vs electric sauna.
It has no Canadian listing: Harvia states CE marking to EN 15821 and EAC only. No wood sauna stove sold in Canada has one, so it is installed to CSA B365 with larger clearances. Check with your building inspector and home insurer before you buy.
WETT (Wood Energy Technology Transfer) certifies wood-heat inspectors in Canada. A WETT inspector checks the stove, the chimney and the clearances against the installation code and writes a report. Most home insurers ask for one before they cover a wood stove; in Quebec the matching body is APC. Ask your insurer whether they need it, before you buy.
The stove is CA$2,304, or CA$2,730.60 with the 120 kg of stones it needs (ticked for you on this page). A working installation also adds a 4-in to 6-in chimney adapter, floor protection on a tiled or wooden floor (the WL100 protective bedding is CA$350.05), and the chimney and its installation. We quote the parts with the stove; the chimney depends on your building and installer.
A room of 6–13 m³ (212–459 ft³), per Harvia. For a larger room, ask about the bigger Legend models or look at an electric heater sized to the room.
Often, yes: the barrel saunas we sell all take wood heat, and the room has to fall inside the stove's 6–13 m³ range. The Canadian Timber Harmony, at 6.3 m³ (222 ft³), does. Plan the clearances first: a barrel's curved walls are wood, and as an unlisted stove the Legend is installed to CSA B365's larger distances.
530 mm across and 740 mm tall, plus 0–30 mm of adjustable legs (about 20.9 × 29.1 in). Harvia gives two empty weights, 58 kg (manual) and 61.5 kg; it weighs about 180 kg with stones.
The SL has a through-wall firebox, so you load wood from outside the hot room. Both suit 6–13 m³ and hold 120 kg of stones; the SL is 730 mm deep and 65.1 kg.
2 years for family use and 6 months for commercial use; accessories 2 years and spare parts 1 year, per Harvia's terms of November 2025. Harvia's extra registration year applies to its electric heaters, not to wood stoves.
Heaters
Wood vs electric sauna in Canada: what an electric heater costs to run by province, firewood, chimney and clearances, WETT, permits and insurance.
Choosing a sauna
Planning a cottage sauna: wood or electric with no power, uncertified stoves and CSA B365, WETT and insurance, fire bans, winterizing and safe lake dips.

Harvia
470 × 665 mm steel plate · 60–75 mm high, 4 adjustable feet · Fits Harvia Legend stoves only
Available to order

Harvia
Ø 300 × 560 mm steel cage · Holds about 40 kg of stones · 165 mm (6½ in) to wood, not 500 mm
Available to order

Harvia
4 L bucket, 37.5 cm ladle · Thermo-hygrometer included · Stainless steel, wood handles
Available to order

Harvia
6–10.5 kW at 240 V · Rooms 4–18 m³ by size · Floor-standing stone tower
Available to order · ships in 3–10 business days

HUUM
4.5–9 kW at 240 V · Wall-mounted, about 55 kg of stones · Rooms 3–13 m³ by size
Available to order

Harvia
6–10.5 kW at 240 V · Rooms 5–18 m³ by size · Black steel, elements apart