Pick electric if you have 240 V power within reach and want a sauna that is ready in 30 to 45 minutes from a switch or an app, with no chimney, firewood or insurer paperwork. Pick wood if there is no power at the site, or you want a fire and accept the permit, chimney, inspection and insurance steps that come with it. To run, a 6 kW electric heater uses about 7–9 kWh for a two-hour sauna: CA$0.64 to CA$1.70 at Ontario's time-of-use energy prices, before delivery charges and tax.

This guide covers what each costs to buy and run, the chimney and clearance rules for a wood stove, and the Canadian permit and insurance questions most comparisons skip. One thing to know up front: the wood stove we sell, the Harvia Legend 150, carries European marks only. That isn't special to the Legend: we found no wood sauna stove on sale in Canada with a Canadian safety listing. The section on listings below explains what that means for your permit, clearances and insurance.

What is an electric sauna?

An electric sauna heater is a box of heating elements and stones on a dedicated 240 V circuit. A separate control sets the temperature and timer, and you switch it on when you want a sauna. Leisurecraft says most electric heaters reach bathing temperature in 30 to 45 minutes, depending on room size and the weather, and that wood stoves usually take a bit longer.

The electric heaters we sell:

  • HUUM DROP: wall-mounted, 4.5 to 9 kW, about 55 kg of stones, controlled by a HUUM UKU (the Wi-Fi version runs from an app). Certified by SGS to the Canadian standard CAN/CSA C22.2 No. 60335-1.
  • Harvia Cilindro: a floor-standing tower, 6 to 10.5 kW, up to 90 kg of stones.
  • Harvia Virta: floor-standing, 6 to 10.5 kW, up to 50 kg of stones.
  • Homecraft Revive Slim: made in Surrey, BC, 4 to 6 kW. Homecraft states it is ETL listed; Intertek's directory shows the heater family as a cETL Recognized Component, so check the label.

Every one needs a licensed electrician to connect it. Breakers run from 30 A for the smallest sizes to 60 A for a 10.5 kW Harvia; see sauna electrical requirements.

How much does it cost to run an electric sauna?

Harvia gives the clearest figures: in a well-insulated room with a correctly sized heater, an hour of heating plus an hour of bathing uses about 7–9 kWh with a 6 kW heater and 9–13 kWh with an 8 kW heater. The heater runs at full power for the first 30–40 minutes, then at about half power to hold the temperature.

At energy-only prices (delivery, regulatory charges and tax come on top), a 6 kW session costs:

  • Quebec, first 40 kWh a day (7.065¢): CA$0.49–$0.64.
  • Ontario off-peak (9.1¢): CA$0.64–$0.82. On-peak (18.9¢): CA$1.32–$1.70.
  • Ontario ultra-low overnight (3.7¢): CA$0.26–$0.33. Ultra-low on-peak, 4 to 9 p.m. weekdays (37.7¢): CA$2.64–$3.39.
  • BC Hydro step 1 (11.87¢): CA$0.83–$1.07.
  • Alberta Rate of Last Resort (about 12¢): CA$0.84–$1.09.

At three sessions a week, about 13 a month, a 6 kW heater comes to roughly CA$6–$8 a month on Quebec's first tier, CA$8–$11 on Ontario off-peak, and CA$11–$14 in BC or Alberta. The full table, with 8 kW figures, is at the end of this guide.

Two cautions. In Quebec, use the higher rate on days your home has already used 40 kWh, which an electrically heated house can pass on a cold day. And an outdoor sauna in January starts colder than Harvia's example; we found no measurement of how much more energy that takes.

What a wood-burning sauna costs to run

Firewood prices vary too much by region for one number, and we found no published Canadian price index, so get two or three local quotes. What you can plan with:

  • A full cord is a stack 1.2 × 2.4 × 1.2 m (4 × 8 × 4 ft), or 3.62 m³ (128 ft³), according to Natural Resources Canada. Check whether a price is for a full cord or a face cord.
  • Dry wood matters. The US EPA advises burning wood at 20% moisture or less; wet wood gives less heat and more smoke.
  • The Legend 150's test figures: a first load of 2.7 kg of wood and refuels of 3.2 kg, at 67% efficiency, per Harvia's declaration of performance under EN 15821.

Wood also costs time: carrying, lighting, refuelling and clearing ash. Some owners count that as part of the ritual; others don't.

Chimney, clearances and the stove itself

A wood stove changes the build. For the Harvia Legend 150 (16 kW, CA$2,304):

  • Room size: rated for 6–13 m³ (212–459 ft³). That suits the Harmony, Tranquility, Panoramic and Georgian; the red cedar barrel (5.5 m³) and MiniPOD (5.9 m³) fall below its range.
  • Chimney: T600-class, on a 115 mm collar. A North American 6 in chimney needs Harvia's adapter, listed at CA$129.95.
  • Clearances to combustibles: 1,000 mm (39⅜ in) above, 200 mm (7⅞ in) at the sides, 250 mm (9 13/16 in) behind and 500 mm (19 11/16 in) in front.
  • Floor: none needed on plain concrete at least 60 mm thick with no wires or pipes in it; otherwise Harvia's WL100 bedding, CA$350.05.
  • Stones: 120 kg, sold separately. The stove itself weighs 58 kg.

In Canada, solid-fuel appliances are installed to the CSA B365 code, and a WETT-certified technician (APC in Quebec) can inspect the work. Not every room takes wood: the Pure Cube and the indoor cabin are electric only, and the MiniPOD's wood layout puts the chimney out the back wall with side-wall benches only.

Can you use a regular wood stove for a sauna?

Use a stove built and tested for saunas. A sauna stove holds a large load of stones and is designed to heat a small room to sauna temperatures; the Legend is tested to EN 15821, the European standard for wood-fired sauna stoves. A household wood stove is certified, and given clearances, for heating a home. Using it in a sauna falls outside that listing, which matters to your building inspector and your insurer. Ask the stove maker and your building department before using any stove outside its listed use.

Permits, WETT and insurance

This is where wood and electric differ most in Canada. An electric heater needs an electrical permit or notification. A wood stove usually needs a building permit, an inspection and a conversation with your insurer.

  • Permits. Many municipalities require a permit for accessory structures over about 10 m² or with wood heat; see sauna permits in Canada. The Township of Guelph/Eramosa requires a building permit for wood-burning appliances. Loyalist Township lists a minimum fee of CA$100.
  • Certified appliances. Loyalist requires the appliance to be certified by ULC, Intertek, CSA or WH. Montréal allows only certified low-emission stoves (EPA 2.5 g/h or less, or CSA B415.1-10), requires a permit and a declaration, and bans burning during smog warnings.
  • Insurance. Loyalist notes that most insurers will ask for a WETT certificate. Wawanesa's solid-fuel questionnaire asks for the chimney's ULC-S629 label and a WETT or APC inspection. Natural Resources Canada advises telling your insurer before you install.

No wood sauna stove in Canada has a Canadian listing

A Canadian listing means a stove has been tested and labelled by a recognized body such as CSA, ULC or Intertek. Henki, an Ontario sauna-stove maker, states that no wood-burning sauna stove sold in Canada is certified by a Canadian recognized certification body. We checked the stoves on sale here, from Harvia, HUUM, Narvi, Leisurecraft, Henki and others, and found none either: they carry European marks, a US test, or nothing. The Harvia Legend 150 we sell has CE (EN 15821) and EAC marks only, with no ULC-S627, UL 1482, CSA B366, EPA or CSA B415.1 certification that we could find.

What that means in practice, according to Henki and Leisurecraft:

  • Installation to CSA B365. Canadian codes still allow a solid-fuel stove installed to the CSA B365 code. Without a listing, B365 sets larger default clearances to walls and benches; shielding can reduce them.
  • An inspection for your insurer. Henki says most Canadian insurers ask for an inspection by a WETT-certified professional (APC in Quebec), and Leisurecraft's stove advice says the same and adds that a backyard sauna should be disclosed to your insurer. Each insurer decides for itself, and some may refuse or charge more.
  • Local rules. Henki notes that some provinces and municipalities restrict selling or using uncertified wood stoves for emissions reasons, and many require a permit for the installation.

Before you buy any wood sauna stove, ask your building department and your insurer, in writing, whether they will accept it.

No power at the site

A wood stove needs no electricity, so it is the practical choice for a cottage, a camp or a far corner of a rural lot with no 240 V service. Running an electric heater on a long cable or a small supply is harder than it sounds: a 9 kW Harvia draws 37.5 A at 240 V. If power is marginal, ask an electrician before you choose.

What each costs up front

Electric (heater, control and stones):

  • HUUM DROP 6 kW + UKU Local + four boxes of stones: CA$2,747.70.
  • Harvia Cilindro 6 kW + Xenio CX30: CA$2,413.80, plus stones.
  • Harvia Virta 6 kW + Xenio CX30: CA$3,336.30, plus stones.
  • Homecraft Revive Slim 4 kW + TKE2-2 control + 100 lb of rocks: about CA$2,183.
  • Then the electrician: published Canadian ranges run from CA$500 to CA$2,500 for a 240 V sauna circuit, plus the permit or notification (ESA's minimum is CA$92 in Ontario).

Wood (Harvia Legend 150):

  • Stove: CA$2,304. Stones: 120 kg, CA$426.60 with the stove on its page.
  • Chimney adapter CA$129.95; floor bedding (WL100 bedding) CA$350.05 if your floor needs it.
  • Chimney: priced by length and route; get a quote for your stove and room.
  • Building permit (from CA$100 in one Ontario township) and a WETT inspection, which we found no published price for.

Both land in the same few-thousand-dollar range once wiring or a chimney is added, but the wood figure has more unknowns: stones, chimney length and the inspection. The bigger difference is what you live with afterward. The full budget is in how much does a sauna cost in Canada.

Which one fits you

  • Electric if the sauna is within reach of your panel, you want it ready on a timer, you live in a city with strict wood-burning rules, or your insurer is wary of wood heat.
  • Wood if there is no power at the site, you are rural with an easy permit path, and your building department and insurer have said yes to the stove in writing.

Browse all sauna heaters and wood stoves, or pick a room first in barrel saunas.

Safety

Saunas are hot by design. Avoid alcohol, start with short sessions and drink water. If you are pregnant or have a heart or other medical condition, talk to your doctor first. With wood: keep the stove's clearances, have the chimney inspected and cleaned, never leave a fire unattended, and ask your building department whether a carbon monoxide alarm is required.

Comparison tables

Heaters we sell: price, power and listing

Scroll the table sideways to see every column.

Prices from our product pages. Electric heaters also need a control and stones; breakers are from the makers' manuals or, for Harvia, a published wiring chart (not from Harvia).
HeaterTypeSizesPrice (CA$)BreakerListing we found
HUUM DROPElectric, wall-mounted4.5–9 kW1,399–1,84030–50 A, 240 VSGS certificate to CAN/CSA C22.2 No. 60335-1
Harvia CilindroElectric, floor tower6–10.5 kW1,447–1,69030–60 A, 240 VcETLus in Harvia's data; not confirmed on a rating plate
Harvia VirtaElectric, floor-standing6–10.5 kW2,472–3,35530–60 A, 240 VcETLus in Harvia's data; not confirmed on a rating plate
Homecraft Revive SlimElectric, floor-standing4–6 kW1,600–1,74530–40 A, 240 VMaker says ETL; Intertek shows a cETL Recognized Component
Harvia Legend 150Wood16 kW2,560NoneCE (EN 15821) and EAC only; no Canadian listing (none found for any wood sauna stove sold in Canada)

What an electric sauna costs to run

Scroll the table sideways to see every column.

Energy price only; delivery, regulatory charges and tax are extra. kWh per session from Harvia: an hour of heating plus an hour of bathing in a well-insulated room. Monthly = 13 sessions (three a week) with a 6 kW heater.
RatePrice per kWh6 kW (7–9 kWh)8 kW (9–13 kWh)6 kW, per month
Quebec, Rate D, first 40 kWh a day7.065¢$0.49–$0.64$0.64–$0.92$6–$8
Quebec, Rate D, above 40 kWh a day11.142¢$0.78–$1.00$1.00–$1.45$10–$13
Ontario, time-of-use off-peak9.1¢$0.64–$0.82$0.82–$1.18$8–$11
Ontario, time-of-use mid-peak14.6¢$1.02–$1.31$1.31–$1.90$13–$17
Ontario, time-of-use on-peak18.9¢$1.32–$1.70$1.70–$2.46$17–$22
Ontario, ultra-low overnight3.7¢$0.26–$0.33$0.33–$0.48$3–$4
Ontario, ultra-low on-peak (4–9 p.m.)37.7¢$2.64–$3.39$3.39–$4.90$34–$44
Ontario, tiered11.2–13.2¢$0.78–$1.19$1.01–$1.72$10–$15
BC Hydro, step 111.87¢$0.83–$1.07$1.07–$1.54$11–$14
BC Hydro, step 214.08¢$0.99–$1.27$1.27–$1.83$13–$16
Alberta, Rate of Last Resort12.01–12.06¢$0.84–$1.09$1.08–$1.57$11–$14

Questions

Is a wood or electric sauna better?

Electric is simpler: it heats in 30 to 45 minutes on a timer, needs no chimney and rarely worries an insurer. Wood works where there is no power and gives you a fire, but brings a permit, a chimney, an inspection and insurance questions.

How much does it cost to run an electric sauna?

A 6 kW heater uses about 7–9 kWh for an hour of heating and an hour of bathing. That is about CA$0.49 to CA$1.70 per session at Quebec, Ontario, BC or Alberta energy prices, before delivery charges and tax, or roughly CA$6 to CA$14 a month at three sessions a week off-peak.

Can you use a regular wood stove for a sauna?

Use a stove made and tested for saunas, such as one tested to EN 15821. A household stove is certified for heating a home, and using it in a sauna falls outside its listing, which matters to inspectors and insurers.

Do I need a permit for a wood-burning sauna?

Often, yes. Many municipalities require a building permit for wood-burning appliances, and some, such as Montréal, allow only certified low-emission stoves. Check with your municipality and your insurer before you buy.

Will my insurer cover a wood-fired sauna?

Ask first. Many insurers ask for a WETT inspection (APC in Quebec), and some ask about the chimney's ULC-S629 label. Tell them the exact stove model and get their answer in writing.

Is the Harvia Legend 150 approved in Canada?

It has CE (EN 15821) and EAC marks only, and we found no wood sauna stove sold in Canada with a Canadian listing. An unlisted stove is installed to CSA B365 with larger clearances, and most insurers want a WETT inspection (APC in Quebec). Ask your building department and insurer in writing before you order.

What is an electric sauna?

A sauna heated by an electric heater: elements warm a load of stones, a control sets the temperature and timer, and the heater runs on a dedicated 240 V circuit connected by a licensed electrician.

Shop sauna heaters & wood stoves

Sources

Models in this guide

  • HUUM DROP heater mounted on a light wood sauna wall, seen between dark glass door frames
    Heat · Electric 240 V

    HUUM

    HUUM DROP Sauna Heater, 4.5–9 kW

    4.5–9 kW at 240 V · Wall-mounted, about 55 kg of stones · Rooms 3–13 m³ by size

    From $1,259.10From $2,581.20 with control and stones

    Available to order

  • Harvia Cilindro PC-E heater in the corner of a light wood sauna beside the benches
    Heat · Electric 240 V

    Harvia

    Harvia Cilindro Sauna Heater, 6–10.5 kW (PC-E)

    6–10.5 kW at 240 V · Rooms 4–18 m³ by size · Floor-standing stone tower

    From $1,302.30From $2,698.20 with control and stones

    Available to order · ships in 3–10 business days

  • Harvia Virta heater with a wooden safety railing beside the benches of a light wood sauna
    Heat · Electric 240 V

    Harvia

    Harvia Virta Sauna Heater, 6–10.5 kW (HL)

    6–10.5 kW at 240 V · Rooms 5–18 m³ by size · Black steel, elements apart

    From $2,224.80From $3,549.60 with control and stones

    Available to order · ships in 3–10 business days

  • Close-up of the Homecraft Revive Slim top stone tray with the Homecraft name cut into the steel
    Heat · Electric 240 V

    Homecraft

    Homecraft Sauna Heater: Revive Slim, 4–6 kW

    4–6 kW at 240 V · Rooms 2.4–9.4 m³ by size · 19 × 34 cm footprint

    From $1,440From $2,182.50 with control and stones

    Available to order · ships in up to 5 days

More guides

  • Install and power

    Sauna electrical requirements in Canada

    What a sauna heater needs in Canada: amps, breaker and wire by kW from the manuals, GFCI rules, 120 V infrared circuits and permits by province.

    12 min read

  • Heaters

    What size sauna heater do I need?

    What size sauna heater do you need? Measure the room in m³, add volume for glass and log walls, then match Harvia, HUUM and Homecraft room ranges.

    9 min read